- Chamber adopts rigid PVC plastic plate, the cover of test chamber uses transparent organic glass, surface is shinning and smooth, acid resistant, temperature resistant and can not be easily aged.
- Automatic water adding system is used, function of making up water automatically when water level is not enough, test can be interrupted in case of water shortage.
- Precise glass nozzle, the sprayed mist particles are small, mist can diffuse evenly, salt mist can naturally settle, the settling amount of salt mist can be adjusted.
- Double overtemperature protection is offered, alarm of lower water level guarantees safety of use.
- Temperature controller with digital display, SSR is controlled with PID, temperature control is correct and reliable, temperature in test chamber and saturation tank become very clear.
- Test chamber uses method of direct heating with steam, the heating rate is high and heating is even, stand-by time can be reduced.
- Spray tower has conical dispenser with functions of directing mist, adjusting mist amount and making mist falling amount even.
- Saturated air barrel uses Henry’s law in heating and humidifying, and offers humidity required by the test chamber.
- The top cover uses water-tight closing way to prevent overflow of salt mist, the chamber cover can be freely opened.
Features:
Standard Configuration
| Model |
YWX |
| 150 |
250 |
750 |
010 |
016 |
020 |
| Performance |
| Temp.range |
R.T+10℃-55℃ |
| Test temperature |
35℃±1℃(NSS), 50℃±1℃(CASS) |
| Temp.constancy |
±0.5℃ |
| Temp.unifomity |
±2℃ |
| Spray volume |
1-2ml/80cm2·h |
| Spray method |
Continue or period |
| Setting time range |
0~9999(H.M.S) |
| Components |
| Chamber material |
Rigid PVC plastic plate |
| Lid material |
Transparent organic glass |
| Saturation tank material |
Stainless steel SUS 304 |
| Heater |
Stainless steel tube heater |
| Controller |
| Chamber temp. Controller |
Controll by microprocessor,SSR export |
| Saturation tank temp. Controller |
Controll by microprocessor,SSR export |
| Operation function |
Fixed temperature operation |
| Safe Device |
| Breaker overcurrent,Test chamber and saturation tank overtemp. protector,Breaker with low water level protector |
| Standard |
| Internal dimensions(mm) |
D |
450 |
600 |
750 |
850 |
850 |
900 |
| W |
600 |
900 |
1100 |
1300 |
1600 |
2000 |
| H |
400 |
500 |
500 |
600 |
600 |
600 |
| External dimensions(mm) |
D |
800 |
960 |
1150 |
1250 |
1250 |
1300 |
| W |
1080 |
1400 |
1750 |
2000 |
2300 |
2700 |
| H |
1080 |
1350 |
1400 |
1550 |
1550 |
1550 |
| Internal volume(L) |
100 |
270 |
400 |
650 |
800 |
1080 |
| Power (KW) |
1.5 |
2 |
3.5 |
5 |
6 |
8 |
| Power Supply |
220V/50HZ |
380V/50HZ |
| Accessories |
| Specimen rack,Measuring cylinder,Trap,Nozzle,Spray tower,Product description |
| Optional Accessories |
| Air compressor/ Additional nozzle |
- The performance shown here is the value under the condition of the ambient temperature of 23°C±2°C, humidity of 65%RH±20%. And there is not burden.